Product details
PROTECTION
Over Load 110%~160%
Protection type: Fold back current limiting, recovers automatically after fault condition is removed
ENVIRONMENT
Working Temp., Humidity -10°C~+60°C;20%~90 %RH
Storage Temp., Humidity -20°C~+85°C;10%~95 %RH
Vibration 10~500Hz,2G 10min./1cycle, period for 60min, each along X, Y, Z axes
SAFETY
Withstand Voltage I/P-O/P: 1.5KVACI/P-FG: 1.5KVACO/P-FG: 0.5KVAC
Isolation Resistance I/P-O/P, I/P-FG, O/P-FG:100M Ohms/500VDC
STANDARD
Safety Standard Design refer to UL1012
EMC Standard Design refer to FCC Part15 J Conduction Class B
1.Low price and high reliability 2.105 output capacitor 3.AC input power suitable for the world 4.High efficiency and low operation temperature 5.Soft-start current can reduce the AC input impact effectively 6.With short-circuit and overload protection 7.Compact size, light weight 8.100% full-load burning test 9.Installed with EMI filter, minimum wave |
Model Specification
|
S-35-5 |
S-35-12 |
S-35-15 |
S-35-24 |
DC output voltage |
5V |
12V |
15V |
24V |
Output voltage error(Note2) |
±2% |
±1% |
±1% |
±1% |
Rated output current |
7A |
3A |
2.4A |
1.5A |
Output current range |
0-7A |
0-3A |
0-2.4A |
0-1.5A |
Wave and noise(Note3) |
75mVp-p |
100mVp-p |
100mVp-p |
100mVp-p |
Inlet stability(Note4) |
±0.5% |
±0.5% |
±0.5% |
±0.5% |
Load stability(Note5) |
±1% |
±0.5% |
±0.5% |
±0.5% |
DC output power |
35W |
36W |
36W |
36W |
Efficiency |
70% |
76% |
78% |
78% |
Adjustable range for DC voltage |
±10,-5% |
±10% |
±10% |
±10% |
AC input voltage range |
85132VAC/170264VACselected by switch |
Input current |
0.85A/115V 0.45A/230V |
AC impulse current |
Cold-start current 18A/115V 36A/230V |
Leakage current |
<0.5mA/240VAC |
Overload protection |
105%150% Type: current limiting; Reset: auto recovery |
Over-voltage protection |
|
High-temperature protection |
|
Temperature coefficient |
±0.03%(050) |
Setup rise hold up time |
200ms,100ms,30ms |
Vibration |
10500Hz,2G 10min./1cycle,Period for 60min,Each axes |
Withstand voltage |
Input and output intermal:1.5KVAC,Input and enclosute:1.5KVAC,Output and enclosure:0.5KVAC |
Isolation resistance |
Input and output interval,Input and enclosure,Output and enclosure0500VAC/100M Ohms |
Working temperature and humidity |
-10+60,20%90%RH |
Store temperature and humidity |
-20+85,10%95RH |
Overall dimension |
129*98*38mm |
Weight |
0.4Kgs |
Safety standards |
Meet UL 1012 requirement(Not apply for the mark) |
EMC standards |
Meet FCC Part 15J Conduction Class B |
Note: 1.The testing condition for the parameter above is:230VAC input, rated load,25 70%Rh,Humidity 2.Error,include the setting error, line stability and load stability.(Note:5) 3.Wave test:adoptingA12double wire for 20MHz,and 0.1uF&uF capacitor short-circuit for interrupting 4.Inlet voltage stability test: when is over load, the lowest voltage of inlet is representative to the highest voltage. 5.Load stability test: The load is from 0% to 100%,others 60%. 6.C2311must be knocked down.
|
|